Rocker Switch and IEC Connector Answers
These are the twenty questions that actually arrive from panel builders, and each answer is short on purpose. Every entry gives the number you need first, then links to the full guide with tolerance tables, derating curves and test data.
Core specifications at a glance
| Parameter | Typical WEUP value | Watch out for |
|---|---|---|
| Panel cutout, KCD4 rocker | 30 x 22 mm, panel 0.8 to 1.5 mm | Oversized hole, bezel pops out |
| Panel cutout, KCD1 rocker | 19 x 13 mm | Thick panels need the long-leg version |
| Contact resistance | 30 mOhm max initial, 50 mOhm after life test | Rises with arc erosion on LED loads |
| Temperature rating | T85, T105, T125 | T85 in a sealed box is a common mistake |
| Motor rating | 16(4) A at 250 VAC | Design to the bracketed figure |
| IEC inlet rating | C14 10 A, C20 16 A at 250 V | Not interchangeable |
What size cutout does a standard rocker switch need?
A 30 x 22 mm cutout fits the common KCD4-type rocker; the smaller KCD1 body uses 19 x 13 mm. Both need a panel of 0.8 to 1.5 mm so the snap legs seat. Cut to the drawing tolerance of plus 0.2 mm and minus 0, because an oversized hole lets the bezel rock and the switch pops out under vibration.
Full guide: Rocker switch panel cutout size chart
Can I use an AC-rated rocker switch on a DC circuit?
Only up to the DC rating printed on the body. A 16 A 250 VAC switch is typically good for about 16 A at 30 VDC or less on resistive loads, and far less on inductive ones. DC arcs do not self-extinguish at a zero crossing, so derate to roughly a quarter of the AC figure for motors and solenoids.
Full guide: AC vs DC switch ratings
What wire gauge, fuse and relay do I need for a 12 V switch?
For 10 A at 12 V use 1.5 mm2 (16 AWG) cable and a 15 A fuse; for 20 A use 2.5 mm2 (14 AWG) and a 25 A fuse. Put the fuse at the battery end of the run. Anything above 10 A continuous should be switched through a relay, not through the panel switch itself.
Full guide: 12 V switch wiring with wire gauge, fuse and relay
What are the IEC 60320 C13, C15 and C19 current ratings?
C13 and C14 are rated 10 A at 250 V (15 A at 125 V). C15 and C16 are also 10 A but rated for 120 C, which is why C15 has a notch for high-temperature appliances. C19 and C20 are 16 A at 250 V (20 A at 125 V) in the larger rectangular body.
Full guide: IEC 60320 ratings for C13, C15 and C19
How is a C14 power entry module wired?
Live and neutral go to the L and N tabs, earth to the PE stud, and the PE stud must be bonded to the chassis with a toothed washer so paint cannot insulate it. The fuse holder sits in the live leg. Leave the PE wire longer than L and N so it is the last conductor to break if the cable is pulled.
Full guide: C14 power entry module wiring
Why do switches fail on LED drivers and motors?
Inrush current. LED drivers pull 20 to 60 times their rated current for a few milliseconds while the input capacitor charges; motors pull 6 to 8 times. A 16 A resistive-rated switch can weld its contacts within weeks. Specify a switch with a tungsten or motor rating and check the inrush figure, not the steady-state amps.
Full guide: Switch inrush current on LED, motor and lamp loads
What is the difference between electrical life and mechanical life?
Mechanical life counts operations with no load, typically 100,000 cycles or more. Electrical life counts operations at rated load, where contact erosion and arcing apply, and is typically 10,000 to 50,000 cycles. Design the panel around the electrical figure, because that is the number the switch actually sees.
Full guide: Electrical life vs mechanical life
IP65, IP67 or IP68: what does a panel switch actually need?
IP65 blocks dust and water jets, IP67 survives 30 minutes at 1 m depth, and IP68 is continuous immersion at a stated depth and time. Most outdoor enclosures only need IP65. Anything above IP65 needs a sealed boot around the actuator, because a sealed switch body alone does not seal the panel hole.
Full guide: IP65 vs IP67 vs IP68 for switches
Which pin is ground on a 3-pin rocker switch?
Usually none of them. On most 3-pin rocker switches the pins are supply, load and, on illuminated versions, the lamp return. A true earth pin is tied to the metal frame and marked with the earth symbol. Confirm with a continuity test to the frame before wiring anything.
Full guide: 3-pin rocker switch wiring: which pin is ground
Is NEMA 4X the same as IP65?
Close but not identical. NEMA 4X adds corrosion resistance and protection against hose-directed water; IP65 covers dust-tightness plus water jets. A NEMA 4X enclosure generally meets or exceeds IP65, but an IP65 rating alone does not imply 4X, because the corrosion test is not part of IP.
Full guide: NEMA vs IP ratings for switches
What do T85, T105 and T125 mean on a switch?
They are maximum ambient temperatures in degrees Celsius: 85 C, 105 C and 125 C. Near heaters, in sealed boxes or beside power resistors, choose T105 or T125. Running a T85 switch above its rating softens the housing, relaxes the contact spring and shortens life even if the current is well within range.
Full guide: Switch temperature ratings T85, T105 and T125
Why does 30 milliohm contact resistance matter?
At 16 A a 30 mOhm contact drops 0.48 V and dissipates 7.7 W inside the switch, which is enough to heat terminals and discolour the housing. Anything above 50 mOhm points to worn or oxidised contacts. Specify 30 mOhm maximum initial and 50 mOhm maximum after the life test.
Full guide: Rocker switch contact resistance of 30 milliohm
5 x 20 mm or 6.3 x 32 mm fuse holder?
5 x 20 mm covers 0.5 to 10 A at 250 V and is the panel standard. 6.3 x 32 mm runs to 16 or 20 A and quenches arcs better because of the longer body. Match holder, fuse and circuit current; never fit a larger fuse to fill a larger holder.
Full guide: 5 x 20 mm vs 6.3 x 32 mm panel fuse holders
What resistor does a 12 V LED rocker switch need?
Work from the lamp, not the switch. For a 2 V 20 mA LED on 12 V: (12 minus 2) divided by 0.02 gives 500 ohm, so use 510 ohm. At 24 V use 1.1 kohm, at 48 V use 2.2 kohm. Many 12 to 24 V illuminated switches already have the resistor built in, so check before adding one.
Full guide: LED resistor values for 12 V, 24 V and 48 V switches
ON-OFF-ON 3-pin vs 6-pin: what is the difference?
A 3-pin ON-OFF-ON is a single-pole changeover with a centre off, so one common feeds either of two outputs. A 6-pin version is two independent changeover circuits switched together, effectively double pole. Use 6-pin when both live and neutral must be broken.
Full guide: ON-OFF-ON 3-pin vs 6-pin wiring
2.8, 4.8 or 6.3 mm spade terminals: which do I use?
Tab width follows current: 2.8 mm to about 6 A, 4.8 mm to about 10 A, 6.3 mm to about 20 A. Match the female terminal to both tab width and tab thickness, which is 0.5 or 0.8 mm. A 6.3 mm terminal crimped loosely onto a 4.8 mm tab is a genuine fire risk.
Full guide: Spade terminal tab widths 2.8, 4.8 and 6.3 mm
C14 vs C20 inlet: which one do I need?
C14 is 10 A at 250 V in a small rectangle with two flat pins plus earth. C20 is 16 A at 250 V in a larger rectangle with different pin spacing, so the two are not interchangeable. Above 10 A continuous, or on equipment that must not trip a 10 A inlet, specify C20.
Full guide: C14 vs C20 inlet difference
What does 16(4) A mean on a switch?
The 16 A is the resistive rating; the 4 A in brackets is the rating for a motor or similar inductive load, usually at 250 VAC and power factor 0.6. It is not a typo and not a range. Motor and compressor circuits must be designed to the bracketed figure, not the headline number.
Full guide: 16(4) A derating for motor loads
IPX4 or IPX6 for an outdoor switch?
IPX4 resists splashing from any direction, which is enough for a covered outdoor panel. IPX6 resists powerful jets and is needed for washdown or exposed marine use. Neither covers dust, so pair the water digit with the solid digit you need, such as IP65 or IP66.
Full guide: IPX4 vs IPX6 for panel switches
How are insulation resistance and dielectric withstand different?
Insulation resistance is measured in megohms at 500 VDC and shows leakage; a good switch reads above 100 MOhm. Dielectric withstand applies 1,500 to 2,000 VAC for one minute and checks that nothing breaks down. The first is a quality indicator, the second is the safety margin.
Full guide: Insulation resistance and dielectric withstand
Where these numbers come from
WEUP manufactures rocker switches, panel fuse holders and IEC 60320 inlets and outlets in Yueqing, China, and supplies OEM panel builders in Europe and North America. The figures above are the release specifications we test against, not catalogue claims: contact resistance is checked at 30 mOhm initial, dielectric withstand at 1,500 VAC for one minute, and life tests run at rated load.
If your application falls outside these bands, send the load type, ambient temperature and panel thickness, and we will quote the switch that fits rather than the closest catalogue item.
Further reading on DEV Community
Two long-form versions of these answers, with the arithmetic behind the numbers, are published on DEV Community: reading a rocker switch nameplate (16(4)A, T85/T125, 30 mΩ, IPX4 vs IPX6) and panel cutouts, fuse holder sizes and C14 vs C20 inlets.