Short answer: inrush is the current a load draws in the first milliseconds after switch-on, and it can be 6–15× the steady current for lamps and motors, and 30× or more for LED drivers. A switch must be selected on the inrush figure, not the running current, or the contacts will pit, stick and eventually weld.
The complaint usually arrives as “your switch failed after two weeks” with a photo of welded contacts. In most cases the switch was not defective. It was a 10 A resistive-rated rocker switching a 4 A load that happened to draw 50 A at every cold start — one hundred times a day.
Inrush multipliers by load type
| Load | Inrush vs steady current | Duration | Why |
|---|---|---|---|
| Resistive heater | 1–1.5× | <10 ms | Nearly constant resistance |
| Incandescent lamp | 10–15× | 10–30 ms | Cold filament resistance is about 1/15 of hot |
| Halogen lamp | 10–20× | 10–30 ms | Same mechanism, hotter filament |
| Motor (induction, universal) | 6–8× | 0.1–2 s | Locked-rotor current until speed builds |
| Compressor / pump | 5–8× | 0.2–3 s | Locked rotor plus pressure head |
| LED driver (capacitive input) | 20–50× | <1 ms | Bulk capacitor charges through a rectifier |
| Transformer (toroidal) | 10–20× | 5–50 ms | Core saturation on first half-cycle |
| Capacitor bank | 50–200× | <1 ms | Direct charging current |
These are typical ranges. The exact figure depends on the load’s impedance at the moment of closing and on the phase of the AC waveform at that instant, which is why two identical lamps can produce different inrush on consecutive switch-ons.
Why the contact fails
When contacts close on a high inrush current, the first contact point is a microscopic area. Current density there melts a spot of metal, which bridges the gap and then solidifies — a micro-weld. At low current the weld is weak and the next opening breaks it. At high inrush the weld area is large enough to hold, and the contacts stay closed. That is why the failure mode of an undersized switch is usually “stuck on”, not “no contact”.
Opening under load produces the opposite damage: an arc that erodes the contact face. A lamp load hits the switch with both problems — high inrush on close and an inductive-ish arc on open.
How to size for inrush
- Find the load’s steady current.
- Multiply by the inrush factor for the load type.
- Compare that figure with the switch’s lamp or motor rating, not its resistive rating. Many datasheets give both, e.g. 16 A resistive and 8 A lamp.
- If the inrush figure exceeds the switch rating, move the load to a relay rated for motor or lamp duty, or choose a switch with an explicitly published tungsten/motor rating.
A common and correct arrangement for a 12 V light bar: the panel rocker switches a 40 A relay coil, and the relay contacts carry the lamp inrush. The switch sees 0.15 A; the relay is rated for the job and is cheap to replace.
Reducing inrush instead of upsizing
- NTC inrush limiter in series with the load: a few ohms cold, near zero hot. Cheap, effective for LED drivers and transformers up to a few hundred watts; it runs warm and needs ventilation.
- Soft-start or pre-charge circuit for large capacitor banks: a resistor bypassed by a relay after 100–300 ms.
- Zero-cross switching with a solid-state relay: closes at the voltage zero crossing, which removes most capacitive inrush.
- Separate control and power circuits: a small switch for the control side and a contactor for the load. Standard in industrial panels for exactly this reason.
A sizing example
A 230 V, 1,000 W halogen heater draws 4.3 A steady, with inrush around 60 A for 20 ms. A 10 A resistive rocker is nominally adequate on current. On lamp duty, however, the correct choice is a switch with a 10 A / 4 A lamp rating at minimum, or a 16 A switch rated for 8 A lamp load, or a relay. The datasheet line to look for is the lamp or tungsten rating, not the headline current.
Frequently asked questions
What is inrush current on a switch?
It is the short, high current drawn by a load immediately after switch-on, caused by cold filaments, motor locked rotor or discharged capacitors. It can be 6–50× the steady current and lasts from under a millisecond to a few seconds.
Why did my 10 A switch fail on a 4 A lamp?
Because the lamp draws 40–60 A for the first 10–30 ms. The switch was chosen on running current, and its lamp rating — if it had one — was below the inrush it actually saw, so the contacts welded.
Do LED lights need a special switch?
LED drivers with capacitive input can draw very high current for under a millisecond. A switch with a published lamp/electronic-load rating, or a relay, avoids the pitting that shows up after a few thousand operations.
Does a higher current rating solve inrush?
It helps, but the rating must correspond to the load type. A 30 A resistive switch may still have a modest lamp rating; check the specific line rather than the headline number.
Tell us the load type and steady current and we will confirm whether a rocker or toggle switch can carry it directly, or whether a relay belongs in the circuit.