Short answer: in 16(4) A 250 VAC the 16 A is the resistive rating and the 4 A in brackets is the inductive rating. A 4 A motor draws 6–8 times that at start, so a 4 A inductive switch is a ceiling, not a comfortable margin. Above roughly 1/3 hp at 230 V, use a relay or contactor.
What the marking encodes
| Marking | Meaning | Load it covers |
|---|---|---|
| 16 A | Resistive rating, AC-1 | Heaters, incandescent lamps (with care), resistive loads |
| (4) A | Inductive rating, AC-15 class | Motors, solenoids, transformers, contactor coils |
| 250 VAC | Rated voltage | Mains single phase |
| T85 / T105 | Max ambient at rated current | Determines derating in a hot box |
Why the bracket is so much smaller
A resistive load is easy: current follows voltage, and the arc at the contact is small. An inductive load stores energy in a magnetic field, and when the contact opens that energy has to go somewhere. The resulting arc erodes the silver, and repeated arcs pit the surface until the contact either welds or goes high resistance.
At make, a motor is worse still. A stopped rotor has almost no back-EMF, so the current is limited only by winding resistance: 6–8 times full-load current for a fraction of a second. The contact closes into that surge every time.
The derating table people actually need
| Load | Inrush multiplier | Safe continuous on a 16(4) A switch |
|---|---|---|
| Resistive heater | 1× | up to 16 A, derated for ambient |
| Incandescent / halogen | 10–15× | about 2–3 A |
| Motor, capacitor start | 6–8× | about 4 A (the bracketed rating) |
| Solenoid, contactor coil | 3–5× | about 4 A |
| LED driver, SMPS input | 20–40× | 1–2 A, or add an NTC |
Doing the sum for a real motor
A 1/3 hp single-phase motor at 230 V draws about 2.6 A full load. Inrush at 7× is roughly 18 A for 100–200 ms. The switch sees 18 A at every start, and the bracketed 4 A rating is the current it can break repeatedly without damage. That combination is at the edge: acceptable for a few thousand starts, marginal for a pump that cycles every minute.
A 1/2 hp motor at 230 V draws about 4 A, inrush near 28 A. This is past what a 16(4) A rocker should break directly. Put a relay in the circuit and let the rocker switch the coil, which draws well under 1 A.
When to stop using the switch as the power device
- Motor above about 1/3 hp at 230 V, or any motor with frequent starts.
- Any load with a capacitor input filter above 2 A continuous.
- Any circuit where the switch is inside a sealed box and already near its T-code.
- Anything with a remote control requirement — a relay gives you low-current wiring to the panel.
FAQ
What does 16(4) A mean on a rocker switch?
16 A resistive and 4 A inductive at 250 VAC. The bracketed figure governs motors, solenoids and transformers.
Can a 16 A switch run a 1 hp motor?
Not directly. 1 hp at 230 V is about 7 A full load with inrush near 45 A; use a contactor rated for the motor.
Does a soft starter remove the need for derating?
It reduces inrush and helps, but the switch still breaks inductive current at every stop, so the bracketed rating still applies.
Why did my switch weld closed on a pump?
Locked-rotor inrush at start exceeded what the contact could make, and the contact spots fused. The fix is a motor-rated relay, not a bigger rocker.
All twenty answers, with cutout sizes, temperature codes and contact limits side by side, are on our switch and connector answers page.