Short answer: T85, T105 and T125 follow IEC 61058-1 and mean the switch may carry its rated current continuously at 85 °C, 105 °C or 125 °C ambient. Below that temperature you have margin; above it you must derate. The actuator side usually has a tighter limit than the terminal side.
What the number is measuring
The T-code answers one question: at what surrounding air temperature can this switch still pass its rated current without its own temperature rise pushing the contacts, housing or terminals past their limits? It is a derating anchor, not a life rating and not a short-circuit rating.
A T85 switch is not “worse” than a T105 switch for a 40 °C application. It is simply certified to a narrower envelope. Buying T125 for an indoor appliance adds cost without adding service life.
Terminal side and actuator side are different limits
Many miniature rocker datasheets publish two ambient figures. A typical KCD1-class part lists terminal side −25 °C to +85 °C and actuating side −25 °C to +55 °C. The reason is mechanical: the actuator is a moulded thermoplastic that must keep its snap force and its legend printing, while the terminal block only has to hold metal and insulation resistance.
This matters when the switch sits behind a warm front panel or next to a heater. A switch that is electrically fine at 80 °C on the terminals can still soften its rocker at 60 °C if the panel itself is that hot.
How hot does a cabinet actually get?
| Location | Typical air temperature | What it means for a T85 part |
|---|---|---|
| Open bench, 25 °C room | 25–30 °C | Ample margin |
| Ventilated enclosure, appliance interior | 40–55 °C | Still inside the envelope |
| Sealed IP65 box with a transformer | 55–70 °C | Little margin left |
| Next to a heater, motor or PSU heatsink | 70–90 °C | T85 is at or past its limit — specify T105 or T125 |
The common mistake is measuring room temperature and assuming the switch sees the same. Inside a closed box, the air around a dissipating component is routinely 20–30 °C above the room.
How to pick the code
- Estimate the air temperature at the switch, not at the enclosure inlet. Measure it running at full load for at least an hour.
- Take the worst case: summer ambient, blocked vents, fan failed.
- Add at least 15–20 °C of headroom to cover self-heating at rated current.
- If the result is above 85 °C, move to T105 or T125 and confirm the actuator material still suits your panel temperature.
Keep in mind that a higher T-code is not a licence to run hotter current. The current rating and the T-code are a pair; at 16 A the internal rise is larger than at 6 A, which is why the same body may be marked 16(4) A 250 VAC T85 or 10 A 250 VAC T105.
Where this shows up in sourcing
When a buyer compares quotations, the T-code is one of the first things that differs between a €0.30 switch and a €0.45 switch with the same external shape. Ask for the marking on the actual moulded body and the corresponding test report, not just the catalogue line. Our rocker switch range lists the T-code per series so the comparison is like for like.
FAQ
Is a T125 switch better than a T85 switch?
Only if your application is genuinely hot. At normal ambient both will outlive the appliance. T125 costs more because of the engineering resins and wider test envelope.
Does the T-code change if I switch less current?
Yes in practice. Self-heating scales with current squared, so at half the rated current the internal rise is roughly a quarter and the usable ambient is higher. Without a derating curve, keep to the marked limit.
Why does my switch feel soft in summer?
The actuator is usually the hottest plastic in the assembly and the first to lose snap force. If the panel exceeds the actuating-side limit, the rocker can deform even though the contacts are healthy.
Can I use a T85 switch in a sealed outdoor box?
Only after measuring the internal temperature at full load. Sealed boxes with sun load commonly run past 70 °C, leaving no margin on a T85 part.
All twenty answers, with cutout sizes, temperature codes and contact limits side by side, are on our switch and connector answers page.
Get a quote for this part
Tell us the quantity and the target price. We reply with price, drawing and lead time.