Short answer: match both dimensions — 2.8 × 0.5 mm, 4.8 × 0.5 mm and 6.3 × 0.8 mm are the common tab pairs. A 6.3 mm receptacle on a 4.8 mm tab grips loosely and heats; a 4.8 mm receptacle forced onto a 6.3 mm tab destroys the spring. Measure width and thickness before ordering.
The pairing table
| Tab width | Inch name | Usual tab thickness | Typical current | Wire |
|---|---|---|---|---|
| 2.8 mm | 0.110 in | 0.5 mm (some 0.8 mm) | up to 6 A | 22–18 AWG |
| 4.8 mm | 0.187 in | 0.5 mm (some 0.8 mm) | up to 10 A | 18–14 AWG |
| 6.3 mm | 0.250 in | 0.8 mm | up to 16 A | 14–10 AWG |
| 9.5 mm | 0.375 in | 1.2 mm | 20 A and above | 10–8 AWG |
These are the sizes used on panel switches, appliance inlets and fuse carriers. Our rocker switches use 4.8 mm and 6.3 mm tabs depending on series, so a mixed panel needs two terminal sizes in stock.
Why thickness matters as much as width
The receptacle is a spring. Its grip comes from two folded lines pressing on the tab plus the dimple that drops into the tab hole. If the tab is thinner than the receptacle was designed for, the spring is not deflected enough: the contact area shrinks, the joint feels loose, and at 10 A it runs warm within minutes. If the tab is thicker, the spring is over-stressed and never returns to shape, so the second mate is looser than the first.
A 6.3 mm tab is normally 0.8 mm thick, but thin-plate 0.5 mm versions exist. That is why measuring only the width is not enough.
How to check a mated joint
- Push the receptacle fully home. It should stop with a click or a definite seat, with no bright tab visible behind the barrel.
- Tug the wire lightly. A correct joint holds; a loose one slides off with fingertip force.
- After 10 minutes at rated load, touch the terminal. Warm is normal; hot means resistance.
- Measure millivolts across the joint under load. Over 50 mV means re-terminate.
Crimp quality is the other half
Even a perfectly sized terminal fails if the crimp is wrong. Look for a crimp where the conductor strands are visible in the window, the insulation support grips the jacket without cutting it, and the barrel is not split. Then pull-test: for 18 AWG a sound crimp holds well above 60 N. A crimp that pulls out at 20 N will fail in a vibrating panel regardless of the tab size.
Insulated or bare
Bare terminals give a better visual crimp inspection and higher temperature tolerance. Insulated versions protect against accidental contact and are required in some appliance standards. In panels where the tab is recessed inside a housing, bare terminals with a boot are common; on exposed terminals near a metal chassis, use insulated receptacles.
FAQ
Can a 6.3 mm terminal fit a 4.8 mm tab?
Physically it slides on, but the grip is poor and the joint overheats. Do not do it.
Are 0.187 in and 4.8 mm the same?
Effectively yes. 0.187 in is 4.75 mm, and the two are sold as the same size.
Do I need a special crimp tool?
Yes for reliable results. Pliers crush the barrel and leave a weak, high-resistance joint that fails the pull test.
How do I remove a spade terminal without damage?
Pull on the terminal body, not the wire, and twist slightly. Pulling the wire stretches the conductor and loosens the crimp.