Short answer: 30 mΩ maximum is the usual acceptance limit for a general-purpose rocker switch, measured by the voltage-drop method at 0.1 A and 6–8 V DC, cold, after a few operations. After electrical life testing the limit typically relaxes to 50–100 mΩ. In the field, under load, a healthy switch drops under 50 mV.
Why the test current is 0.1 A and not 16 A
Contact resistance is dominated by surface films, oxide layers and micro-asperities at low current. At 0.1 A the film is not broken down, so the reading reflects the real interface quality. At rated current the contact spots heat, soften and partly weld, and the measured resistance drops sharply.
That is why you should not take the 30 mΩ figure and multiply it by 16 A to predict dissipation. 30 mΩ × 16 A² would suggest an impossible wattage. The datasheet number is a manufacturing screening limit, not a thermal model.
The standard test condition
| Item | Condition | Typical limit |
|---|---|---|
| Method | Voltage-drop method, four-wire | — |
| Test current | 0.1 A, 6–8 V DC | — |
| State | Cold, after a few no-load operations | — |
| Contact resistance, initial | Terminal to terminal, closed | 30 mΩ max |
| After electrical life | Typically 10,000 cycles | 50–100 mΩ max |
| Insulation resistance | 500 V DC, 1 min | 100 MΩ min |
These are the conditions published for our KCD1-104 series: contact resistance measured at 0.1 A, 6–8 V DC by voltage drop, 30 mΩ maximum before life test and 50 mΩ after part of the sequence.
How to check a switch on the bench
- Use a four-wire milliohm meter, or a lab supply set to 0.1 A with a mV meter across the closed contacts.
- Cycle the switch five times without load, then measure in the closed position.
- Measure each contact pair separately — a DPDT can have one good pole and one bad pole.
- Repeat at the end of a temperature soak if the part will run hot; film resistance is temperature sensitive.
The field test that actually finds failures
A continuity beeper is useless here: it pushes less than 1 mA through the contact and will happily buzz on a contact that fails at 10 A. The useful test is voltage drop under real load.
- Switch on the load so real current flows.
- Set the meter to DC or AC millivolts and probe across the two terminals of the closed contact.
- Under 50 mV: healthy.
- 50–100 mV: degraded, plan a replacement.
- Over 100 mV: the contact is generating heat, replace before it burns the housing.
At 10 A, 100 mV means 1 W inside a switch the size of a thumbnail. That is enough to discolour the nylon and eventually carbonise the track.
What drives the number up
Silver contacts pit under inductive arcing; tungsten-lamp and capacitive inrush weld and then roughen the surface; flux residue and humidity build a resistive film; and a terminal screw left loose adds its own milliohms in series. If a batch suddenly measures 45 mΩ instead of 25 mΩ, look at plating thickness and the crimp or screw torque before blaming the design.
FAQ
Is 30 mΩ a good value for a 16 A switch?
It is the normal limit for a general-purpose rocker in this class. Values around 20 mΩ indicate a well-controlled contact system; values above 50 mΩ out of the box should be rejected.
Can I measure contact resistance with a normal multimeter?
Not reliably. A two-wire meter includes lead and probe resistance, often 200–400 mΩ, which swamps the reading. Use four-wire measurement or the loaded voltage-drop method.
Does contact resistance rise with age even without load?
Yes. Storage in humid air grows a sulfide or oxide film on silver, which is why switches that sat for a year can read higher until the first few loaded operations clean the surface.
What voltage drop is acceptable across a switch?
Under 50 mV at rated current. Above 100 mV the dissipation is high enough to damage the housing and should be treated as a failure.